Spend $25 to be eligible for FREE SHIPPING!
Minimum order activates Free Shippingoption on check out page.
Overhaul
Overhaul
Overhaul: The All-in-One Solution for Peak System Performance and Long Life
Improve your system's performance with Overhaul, the innovative one-step treatment that combines the power of Vapco's System Protect and System Enhance Xpress Inject products.
Overhaul is the ultimate solution for:
- Boosting Efficiency: Overhaul improves your system, leading to increased efficiency and improved overall performance.
- Combating Moisture and Acid: This unique formula eliminates moisture and prevents acid formation, protecting your system from internal damage and corrosion.
- Extending System Life: Overhaul helps extend the lifespan of your system, saving you money on replacements in the long run.
Here's how Overhaul achieves these remarkable results:
- Dual-Action Formula: Overhaul combines the benefits of System Protect and System Enhance Xpress Inject, delivering a comprehensive treatment in a single application.
- Acid Neutralization: Overhaul effectively neutralizes and removes existing acid buildup, preventing further damage and corrosion.
- Moisture Removal: This powerful formula eliminates moisture that can lead to electrical problems and system malfunctions.
- Friction Reduction: Overhaul reduces friction within the system, minimizing wear and tear and lowering operating noise.
- Burnout Prevention: By addressing key performance factors, Overhaul helps safeguard your system from costly burnouts.
The Benefits of Overhaul:
- Increased Efficiency: Enjoy optimal system performance and lower energy consumption.
- Reduced Noise: Experience quieter operation with minimized noise levels.
- Prevents Acid Damage: Protect your system from internal corrosion caused by acid buildup.
- Moisture Elimination: Eliminate moisture to prevent electrical problems and malfunctions.
- Burnout Protection: Reduce the risk of system burnouts and extend equipment life.
- Reduced Strain and Friction: Minimize wear and tear for smoother operation.
Invest in Overhaul today and experience the combined benefits of peak performance, extended system life, and superior protection!
Here's What's New in HVAC: Your Trusted Partner for System Maintenance and Optimization
At Here's What's New in HVAC, we offer a wide range of innovative products like Overhaul to help you maintain and optimize your systems for maximum efficiency and longevity. Browse our comprehensive online store and discover everything you need to keep your systems running smoothly and efficiently for years to come.
This is a professional grade HVAC product. It is crucial that you adhere to all directions and precautionary statements to prevent injuries.
Directions
Directions
Directions Using Vapco’s Direct Inject Gun:
Turn the A/C system on and verify the unit is running.
With the CO2 cartridge in the gun, connect the Xpress Seal to the Direct Inject Gun.
Connect the other end to the low-side service port. Briefly pull the trigger.
The direct Inject Gun will meter just enough CO2 to empty tube.
The sealer has now been injected into the system.
Disconnect the empty tube from the low-side port. Install service port cap.
Run the A/C unit at least one hour after installing Xpress Seal.
12+ uses per CO2 cartridge.
For traditional methods using refrigerants to install Xpress Seal use the following instructions:
Turn the a/c system on and verify the unit is running.
Connect Xpress Seal to the low-side service port of the system. (This is generally the large line).
Connect the manifold refrigerant hose to the refrigerant supply tank.
Verify the high and low side valves on the manifold are closed before proceeding.
Purge the low pressure hose when connecting to Xpress Seal.
Open low-side valve and watch for the tube to clear. (This will ONLY take a few seconds!)
Turn off low-side manifold valve as soon as the tube is clear.
Turn off refrigerant gas. Verify the system is charged to manufacturer’s specifications!
Disconnect low-side hose from Xpress Seal.
Remove Inject.
Install service port cap.
Run the a/c unit at least one hour after installing Xpress Seal. (Do not bend or kink hose!)
Read and understand the product’s label and Safety Data Sheet. DO NOT mix with ammonia, DO NOT use in any manner for which it was not designed. Always wear PPE (Personal Protective Equipment) when servicing HVAC equipment.
Precautionary Statements
Precautionary Statements
Read and understand the product’s label.
DO NOT mix with ammonia, DO NOT use in any manner for which it was not designed.
Always wear PPE (Personal Protective Equipment) when servicing HVAC equipment.
PRECAUTIONS: Do NOT handle or use this product until all safety precautions have been read and understood. Keep away from heat/sparks/open flame/hot surfaces.
NO SMOKING! Do not breathe dust/fume/gas/mist/ vapors/spray.
Wash hands and arms thoroughly after handling.
Use only outdoors or in a well-ventilated area.
Avoid release to the environment.
Wear protective gloves/clothing/face/eye protection.
FIRST AID MEASURES: Inhalation: If symptoms occur, go to open air and ventilate suspected area. Immediately call a POISON CENTER or doctor/physician.
Skin contact: Wash skin with soap and water. If irritation persists, seek medical attention.
Eye Contact: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physician.
Ingestion: Do NOT induce vomiting. Immediately call a POISON CENTER or doctor/physician.
IN CASE OF FIRE: Use dry chemical powder, alcohol-resistant foam or carbon dioxide.
STORAGE: Keep temperatures below 52oC/125oF. Store in a dry/cool/well ventilated place. Store locked up.
Incompatible products: Heat sources and oxidizers.